Dynamic Rotating Countersink ECP:
- typical differential probe built according to the “Reflection” scheme, the sensing element of which is built into the plastic (or rigid wearproof metal) case
- designed for testing of holes countersink surface of a given diameter (an ECP is selected to a specific countersink angle and a hole guiding diameter)
- applied together with eddy current rotary scanners SVR-04/SVR-05 (OKOndt Group)
- compatible with the rotary scanners Mini Mite (OLYMPUS), Mini Drive (GE) and others
- applied together with the eddy current flaw detectors Eddycon C, Eddycon CL and flaw detectors from other producers.
Designation | Guide hole diameter “D”, mm/inch | Countersink angle, degr. | Length, mm | Frequency | Connector | Material |
RCP-100˚- 3.17 | 3.17/.125 | 100 | 64 | 200 kHz -3 MHz | 4-pin Fischer connector (to Hocking, GE, Rohmann and Forester drive units, etc.) | Fe/NFe |
RCP-100˚- 3.96 | 3.96/.156 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 4 | 4/.157 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 4.75 | 4.75/.187 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 5 | 5/.197 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 6 | 6/.236 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 6.34 | 6.34/.25 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 7 | 7/.276 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 7.92 | 7.92/.312 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 9 | 9/.354 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 9.52 | 9.52/.375 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 11 | 11/.433 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 11.09 | 11.09/.437 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 12.69 | 12.69/.5 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 13 | 13/.512 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 14.26 | 14.26/.562 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 15 | 15/.59 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 15.86 | 15.86/.625 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 17.44 | 17.44/.687 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe | |
RCP-100˚- 19.03 | 19.03/.75 | 100 | 64 | 200 kHz -3 MHz | Fe/NFe |
RCP | - | 100˚ | - | 3.17 | (SS/Sh) |
1 |
| 2 |
| 3 | 4 |
RCP – dynamic rotating probe for hole countersinks testing.
Countersink angle, degr.
Range of hole size, mm.
Guide hole diameter, mm.
The housing of a standard probe is made of delrin; in case a stainless steel housing is required, please indicate the letters “SS”(Stainless Steel) at the end of a probe designation code in your order.
It is possible to manufacture the probes for countersink testing with other angles. For this, the required countersink angle should be specified in the order.