Intended use of the ОKО-22М-UT ultrasonic flaw detector
The ОKО-22М-UT is available in several configurations with the varying number of ultrasonic channels and result processing functions.
The flaw detector is a standalone device. While connected to the PC via the Ethernet port, the ОKО-22М-UT can become part of the multi-channel testing system with a few UT channels connected to the PC via the switch unit.
Application of Ultrasonic Testing Techniques in Industries
Production sector, test object | Regulatory Documentation | Required number of channels | Operating frequency, MHz | Testing techniques |
Metallurgy, testing the flat rolled steel | EN10160, ASTM 578/A578M-96, A435A, ISO 12094 | 60-100 | 2-5 | Immersion or contact |
Metallurgy, testing the rolled round steel bars | EN 10308, EN 10228-3, ASTM E – 2375, MS-STD – 2154 | 3-20 | 2-10 | Immersion or contact, testing velocity is up to 2 m/s |
Engineering, testing the pipe welded joints | API 5L, API5 CT, EN 10246-17 | 12 | 2-5 | Immersion or contact, velocity is up to 2 m/s |
Engineering, testing the pipe body, thickness gauging | API 5L, API5CT, EN 10246, ASTM E1816-96 | 56 | 2-5 | Immersion or contact, velocity is up to 1 m/s. Resonance-frequency technique for measuring the pipe |
Figure 1 – UT channel "ОКО-22М"
Figure 2 - Structural scheme for connecting the UT channels
Parameter | Value |
PULSER | |
Pulse mode | Spike pulser, Square-Wave pulser |
Pulse Voltage (SQ mode) | 120-300 V in steps 10 V with tolerance 10% |
Pulse falling/rising time | 5 ns |
Pulse Width (SQ mode) | 20 – 500 ns in steps 10 ns with tolerance 10% |
PRF (SQ mode) | 15 – 2000 Hz in steps 5 Hz, 3 automatic modes: Auto Low, Auto Med, Auto High, Manual |
Pulse Voltage (spike mode) | Low (100 V), High (400 V) |
Pulse energy (spike mode) | Low (30 ns), High (100 ns) |
PRF (spike mode) | 15 – 8000 Hz in steps 5 Hz, 3 automatic adjustment modes: Auto Low, Auto Med, Auto High, Manual |
Damping | 50, 62, 150, 400 |
RECEIVER | |
Gain | 0 to 110 dB adjustable in steps of 0.2, 0.5, 1, 2 dB |
Receiver input impedance | 400Ω±5% |
Receiver bandwidth | 0.2-27 MHz (- 3 dB) |
Digital filter setting | Eight digital filter sets standard (0.2-10 MHz; 2.0-21.5 MHz; 8.0-26.5 MHz; 0.5-4 MHz; |
Rectification | Fullwave, positive halfwave, negative halfwave, RF |
Amplitude measurement | 0-110% |
Reject | 0-80% FSH |
Units | Millimeters, inch or microseconds |
Range | 1 to 6000 mm |
Velocity range | 1000 to 10000 m/s in steps of 1, 10, 100, 1000 m/s |
Thickness measurements range | 0.6 to 6000 mm |
Probe angle | 00 to 900 in steps 0.10, 1.00, 100 |
DIGITAL SPECIFICATION | |
ADC | 10 – bits with the sampling rate 100 MHz |
A-Scan buffer | 8 KB |
GATE | |
Measurements gates |
|
Start Gate | Variable over entire range |
Width Gate | Variable over entire range |
Gate height | Variable from 2 to 100% FSH |
MEASUREMENT SPECIFICATION | |
Result display | A-scan, B-scan, C-scan, D-scan, TOFD scan |
DAC/TCG |
|
DGS |
|
CONNECTORS | |
Probe connector | 2 BNC or 2 Lemo 1S |
USB port | USB-2.0 |
Ethernet | + |
Alarm output | + |
Encoder | 1 Lemo (with the option of two encoders operation) |